Matching Items (12,692)
Filtering by

Clear all filters

Description

DNA is useful for electronic applications due to its self-assembly and electronic properties. It can be improved for this purpose through the addition of metal ions. In this experiment, DNA was modified with silver ions and carbon nanotubes were attached to both ends. The DNA-CNTs were connected over a 300

DNA is useful for electronic applications due to its self-assembly and electronic properties. It can be improved for this purpose through the addition of metal ions. In this experiment, DNA was modified with silver ions and carbon nanotubes were attached to both ends. The DNA-CNTs were connected over a 300 nm gap between gold electrodes using cysteamine. The conductance was found to be 1.28*10-4 G0, which is similar to literature values for unmodified DNA. Therefore, modifying DNA with silver ions was not found to significantly improve the conductance. It was also found that smaller applied voltages need to be used because of electrochemistry happening above 1 V.

ContributorsAbbas, Isabelle (Author) / Forzani, Erica (Thesis director) / Hihath, Joshua (Committee member) / Barrett, The Honors College (Contributor) / Chemical Engineering Program (Contributor) / Materials Science and Engineering Program (Contributor)
Created2023-05
Description

Ketone levels give an insight into the bodies metabolism. People with epilepsy or people dieting may want to keep their levels high, whereas type one diabetics or those recovering from eating disorders may want to keep their levels low. Current ketone detection methods involve blood samples or urinalysis. A ketone

Ketone levels give an insight into the bodies metabolism. People with epilepsy or people dieting may want to keep their levels high, whereas type one diabetics or those recovering from eating disorders may want to keep their levels low. Current ketone detection methods involve blood samples or urinalysis. A ketone (acetone) biosensor was fabricated to detect levels in human breath, providing a noninvasive way to quickly and accurately detect ketone levels in the body.

ContributorsHendricks, Asher (Author) / Forzani, Erica (Thesis director) / Osorio Perez, Oscar (Committee member) / Wang, Shaopeng (Committee member) / Barrett, The Honors College (Contributor) / Chemical Engineering Program (Contributor)
Created2023-05
Description

Energy Expenditure (EE) (kcal/day) is a key parameter used to guide obesity treatment, and it is often measured from CO2 production, VCO2 (mL/min), and/or O2 consumption, VO2 (mL/min) through the principles of indirect calorimetry. Current EE measurement technologies are limited due to the requirement of wearable facial accessories, which can

Energy Expenditure (EE) (kcal/day) is a key parameter used to guide obesity treatment, and it is often measured from CO2 production, VCO2 (mL/min), and/or O2 consumption, VO2 (mL/min) through the principles of indirect calorimetry. Current EE measurement technologies are limited due to the requirement of wearable facial accessories, which can introduce errors as measurements are not taken under free-living conditions. A novel contactless system, the SmartPad, which measures EE via VCO2 from a room’s ambient CO2 concentration transients was evaluated. First, SmartPad accuracy was validated by comparing the SmartPad’s EE and VCO2 measurements with the measurements of a reference instrument, the MGC Ultima CPXTM, in a cross-sectional study consisting of 20 subjects. A high correlation between the SmartPad’s EE and VCO2 measurements and the MGC Ultima CPX’s EE and VCO2 measurements was found, and the Bland-Altman plots contained a low mean bias for EE and VCO2 measurements. Thus, the SmartPad was validated as being accurate for VCO2 and EE measurements. Next, resting EE (REE) and exercise VCO2 measurements were recorded using the SmartPad and the MGC Ultima CPXTM at different operating CO2 threshold ranges to investigate the influence of measurement duration on system accuracy in an effort to optimize the SmartPad system. The SmartPad displayed 90% accuracy (±1 SD) for 14–19 min of REE measurement and for 4.8–7.0 min of exercise, using a known room’s air exchange rate. Additionally, the SmartPad was validated by accurately measuring subjects’ REE across a wide range of body mass indexes (BMI = 18.8 to 31.4 kg/m^2) with REEs ranging from ~1200 to ~3000 kcal/day. Lastly, the SmartPad has been used to assess the physical fitness of subjects via the “Contactless Thermodynamic Efficiency Test” (CTET).

ContributorsVictor, Shaun (Author) / Forzani, Erica (Thesis director) / Wang, Shaopeng (Committee member) / Barrett, The Honors College (Contributor) / Watts College of Public Service & Community Solut (Contributor) / Harrington Bioengineering Program (Contributor)
Created2022-05
Description

Realtime understanding of one’s complete metabolic state is crucial to controlling weight and managing chronic illnesses, such as diabetes. This project represents the development of a novel breath acetone sensor within the Biodesign Institute’s Center for Bioelectronics and Biosensors. The purpose is to determine if a sensor can be manufactured

Realtime understanding of one’s complete metabolic state is crucial to controlling weight and managing chronic illnesses, such as diabetes. This project represents the development of a novel breath acetone sensor within the Biodesign Institute’s Center for Bioelectronics and Biosensors. The purpose is to determine if a sensor can be manufactured with the capacity to measure breath acetone concentrations typical of various levels of metabolic activity. For this purpose, a solution that selectively interacts with acetone was embedded in a sensor cartridge that is permeable to volatile organic compounds. After 30 minutes of exposure to a range of acetone concentrations, a color change response was observed in the sensors. Requiring only exposure to a breath, these novel sensor configurations may offer non-trivial improvements to clinical and at-home measurement of lipid metabolic rate.

ContributorsDenham, Landon (Author) / Forzani, Erica (Thesis director) / Mora, Sabrina Jimena (Committee member) / Barrett, The Honors College (Contributor) / Chemical Engineering Program (Contributor)
Created2022-05
Description
It is well established that physical activity (PA) directly correlates with many health benefits, especially when active habits are formed during childhood and adolescence. PA practiced in adolescence has been seen to carry into adulthood, helping to combat a host of chronic diseases, such as obesity and diabetes. However, in

It is well established that physical activity (PA) directly correlates with many health benefits, especially when active habits are formed during childhood and adolescence. PA practiced in adolescence has been seen to carry into adulthood, helping to combat a host of chronic diseases, such as obesity and diabetes. However, in recent years there has been a steady decline in PA among adolescents, followed by a resulting rise in sedentary behavior. Walking Intervention Through Texting for Adolescents, or WalkIT-A, was an 11.5-week intervention that built upon behavioral theory to provide an incentive-based, adaptive, physical activity intervention to inactive adolescents. The goal of this study was to investigate an intervention which combined walking with pointed behavior change strategies to incite a larger increase in PA. Using single-case, reversal (ABA) design, the study was aimed at shaping physical activity behavior in adolescents aged 12-17 through a mobile health intervention that paired adaptive goal setting with financial incentives to increase step count. The intervention was delivered using a semi-automated texting, mobile-Health (mHealth) platform, which incorporated FitBit tracking technology, adaptive goals, motivational messages, performance feedback, and points/incentives. It was hypothesized that during the adaptive intervention phase participants would increase both steps per day and active minutes compared to baseline values. Upon conclusion of the study, the three adolescent participants exhibited increased steps and active minutes during the intervention period compared to baseline and withdrawal phases. However, the specific trends identified suggest the need for future research to incorporate even stronger intervention components to overcome PA "drop-off" midway through the intervention, along with other external, environmental influencers. Despite this need, the use of adaptive goal setting combined with incentives can be an effective means to incite PA behavior change in adolescents.
ContributorsVan Bussum, Courtney Jessica (Author) / Adams, Marc (Thesis director) / Forzani, Erica (Committee member) / Harrington Bioengineering Program (Contributor) / Barrett, The Honors College (Contributor) / School of Nutrition and Health Promotion (Contributor)
Created2016-12
Description
Arson and intentional fires account for significant property losses and over 400 civilian deaths yearly in the United States. However, clearance rates for arson offenses remain low relative to other crimes. This issue can be attributed in part to the challenges associated with performing an arson investigation, in particular the

Arson and intentional fires account for significant property losses and over 400 civilian deaths yearly in the United States. However, clearance rates for arson offenses remain low relative to other crimes. This issue can be attributed in part to the challenges associated with performing an arson investigation, in particular the collection and interpretation of reliable data. PLOT-cryoadsorption, a dynamic headspace sampling technique developed at the National Institute of Standards and Technology, was proposed as an alternate technique for extracting ignitable liquid residues for analysis. The method was generally shown to be robust, flexible, precise, and accurate for a variety of applications. The possibility of using a real-time in situ monitor for screening samples was also discussed. This work, conducted by an undergraduate researcher, has implications in educational curricula as well as in the field of forensic science.
ContributorsNichols, Jessica Ellen (Author) / Forzani, Erica (Thesis director) / Nielsen, David (Committee member) / Tsow, Francis (Committee member) / Barrett, The Honors College (Contributor) / School of Mathematical and Statistical Sciences (Contributor) / Chemical Engineering Program (Contributor)
Created2013-05
Description
Detection of molecular interactions is critical for understanding many biological processes, for detecting disease biomarkers, and for screening drug candidates. Fluorescence-based approach can be problematic, especially when applied to the detection of small molecules. Various label-free techniques, such as surface plasmon resonance technique are sensitive to mass, making it extremely

Detection of molecular interactions is critical for understanding many biological processes, for detecting disease biomarkers, and for screening drug candidates. Fluorescence-based approach can be problematic, especially when applied to the detection of small molecules. Various label-free techniques, such as surface plasmon resonance technique are sensitive to mass, making it extremely challenging to detect small molecules. In this thesis, novel detection methods for molecular interactions are described.

First, a simple detection paradigm based on reflectance interferometry is developed. This method is simple, low cost and can be easily applied for protein array detection.

Second, a label-free charge sensitive optical detection (CSOD) technique is developed for detecting of both large and small molecules. The technique is based on that most molecules relevant to biomedical research and applications are charged or partially charged. An optical fiber is dipped into the well of a microplate. It detects the surface charge of the fiber, which does not decrease with the size (mass) of the molecule, making it particularly attractive for studying small molecules.

Third, a method for mechanically amplification detection of molecular interactions (MADMI) is developed. It provides quantitative analysis of small molecules interaction with membrane proteins in intact cells. The interactions are monitored by detecting a mechanical deformation in the membrane induced by the molecular interactions. With this novel method small molecules and membrane proteins interaction in the intact cells can be detected. This new paradigm provides mechanical amplification of small interaction signals, allowing us to measure the binding kinetics of both large and small molecules with membrane proteins, and to analyze heterogeneous nature of the binding kinetics between different cells, and different regions of a single cell.

Last, by tracking the cell membrane edge deformation, binding caused downstream event – granule secretory has been measured. This method focuses on the plasma membrane change when granules fuse with the cell. The fusion of granules increases the plasma membrane area and thus the cell edge expands. The expansion is localized at the vesicle release location. Granule size was calculated based on measured edge expansion. The membrane deformation due to the granule release is real-time monitored by this method.
ContributorsGuan, Yan (Author) / Tao, Nongjian (Thesis advisor) / LaBaer, Joshua (Committee member) / Goryll, Michael (Committee member) / Wang, Shaopeng (Committee member) / Arizona State University (Publisher)
Created2015
Description
For the increasing concerns of influence on environment by fossil-electricity generation, application of renewable energy becomes one of the most focused issues in society. Based on the limitation on urban environment, wind turbines, which can be mounted on rooftop or between buildings, are regarded as a feasible way for wind

For the increasing concerns of influence on environment by fossil-electricity generation, application of renewable energy becomes one of the most focused issues in society. Based on the limitation on urban environment, wind turbines, which can be mounted on rooftop or between buildings, are regarded as a feasible way for wind energy generation. This study presents wind flow simulations in a large-scale environment with certain dimension buildings. Different inlet velocity boundary conditions are tested firstly, and the non-uniform inlet boundary condition shows better agreement with realistic situation. Turbulence intensity is set to be 10% for comparison consistency. The k-epsilon turbulence model is regarded as a better simulation for this certain condition. After that, three different structures, which include single building, pristine double building and modified circular gap double building systems, are tested in this environment condition. The result shows 18.8% velocity increasing on the top of single building system. Pristine double building systems are tested with 4 different gap distances, and building with 10 meters gap achieved the best velocity condition, which 32.8% velocity increasing and 11.8% improvement comparing to single building system, respectively. But the location of maximum velocity moves to the gap and the maximum velocity on the rooftop of double building system is approximately 5.1% lower than single building system. Based on previous study, modified circular gap double building system is created with 10 meters gap. Comparing result with single building system, modified circular gap system achieves higher improvement for wind flow, whose improvement of velocity increasing in the gap and on the rooftop of building are 47.1% and 3.0%, respectively. As a result, the modified circular gap double building can be regarded as a high efficiency system of environmental wind flow over buildings for renewable energy system.
ContributorsLi, Guoyi (Author) / Huang, Huei-Ping (Thesis advisor) / Lee, Taewoo (Committee member) / Forzani, Erica (Committee member) / Arizona State University (Publisher)
Created2015
Description
Environmentally responsive microgels have drawn significant attention due to their intrinsic ability to change volume in response to various external stimuli such as pH, temperature, osmotic pressure, or electric and magnetic fields. The extent of particle swelling is controlled by the nature of the polymer-solvent interaction. This thesis focuses on

Environmentally responsive microgels have drawn significant attention due to their intrinsic ability to change volume in response to various external stimuli such as pH, temperature, osmotic pressure, or electric and magnetic fields. The extent of particle swelling is controlled by the nature of the polymer-solvent interaction. This thesis focuses on design and synthesis of environmentally responsive microgels and their composites, and encompasses methods of utilizing microgel systems in applications as vehicles for the adsorption, retention, and targeted delivery of chemical species. Furthermore, self-assembled microgel particles at ionic liquid (IL)-water interfaces demonstrate responsive colloidal lattice morphology. The thesis first reports on the fundamental aspects of synthesis, functionalization, and characteristic properties of multifunctional environmentally responsive microgels derived from poly(N-isopropylacrylamide) (PNIPAm) and other functional co-monomers. In particular, the uptake and release of active chemical species such as rheology modifiers into and from these ionic microgels is demonstrated. Moreover, a facile tunable method for the formation of organic-inorganic composites with Fe3O4 nanoparticles adsorbed and embedded within ionic microgel particles is explored. Additionally, the development of zwitterionic microgels (ZI-MG) is presented. These aqueous ZI-MG dispersions exhibit reversible parabolic swelling as a function of pH and display a minimum hydrodynamic diameter at a tunable isoelectric point (IEP). This study also elucidates the controlled uptake and release of surfactants from these particle systems. The extent of surfactant loading and the ensuing relative swelling/deswelling behaviors within the polymer networks are explained in terms of their binding interactions. The latter part of this thesis highlights the versatility of fluorescently labeled microgel particles as stabilizers for IL-water droplets. When the prepared particles form monolayers and equilibrate at the liquid-liquid interface, the colloidal lattice organization may re-order itself depending on the surface charge of these particles. Finally, it is shown that the spontaneously formed and densely packed layers of microgel particles can be employed for extraction applications, as the interface remains permeable to small active species.
ContributorsChen, Haobo (Author) / Dai, Lenore L (Committee member) / Chen, Kangping (Committee member) / Forzani, Erica (Committee member) / Lind, Mary Laura (Committee member) / Mu, Bin (Committee member) / Arizona State University (Publisher)
Created2015
Description
Vapor intrusion (VI) pathway assessment often involves the collection and analysis of groundwater, soil gas, and indoor air data. There is temporal variability in these data, but little is understood about the characteristics of that variability and how it influences pathway assessment decision-making. This research included the first-ever collection

Vapor intrusion (VI) pathway assessment often involves the collection and analysis of groundwater, soil gas, and indoor air data. There is temporal variability in these data, but little is understood about the characteristics of that variability and how it influences pathway assessment decision-making. This research included the first-ever collection of a long-term high-frequency indoor air data set at a house with VI impacts overlying a dilute chlorinated solvent groundwater plume. It also included periodic synoptic snapshots of groundwater and soil gas data and high-frequency monitoring of building conditions and environmental factors. Indoor air trichloroethylene (TCE) concentrations varied over three orders-of-magnitude under natural conditions, with the highest daily VI activity during fall, winter, and spring months. These data were used to simulate outcomes from common sampling strategies, with the result being that there was a high probability (up to 100%) of false-negative decisions and poor characterization of long-term exposure. Temporal and spatial variability in subsurface data were shown to increase as the sampling point moves from source depth to ground surface, with variability of an order-of-magnitude or more for sub-slab soil gas. It was observed that indoor vapor sources can cause subsurface vapor clouds and that it can take days to weeks for soil gas plumes created by indoor sources to dissipate following indoor source removal. A long-term controlled pressure method (CPM) test was conducted to assess its utility as an alternate approach for VI pathway assessment. Indoor air concentrations were similar to maximum concentrations under natural conditions (9.3 μg/m3 average vs. 13 μg/m3 for 24 h TCE data) with little temporal variability. A key outcome was that there were no occurrences of false-negative results. Results suggest that CPM tests can produce worst-case exposure conditions at any time of the year. The results of these studies highlight the limitations of current VI pathway assessment approaches and demonstrate the need for robust alternate diagnostic tools, such as CPM, that lead to greater confidence in data interpretation and decision-making.
ContributorsHolton, Chase Weston (Author) / Johnson, Paul C (Thesis advisor) / Fraser, Matthew (Committee member) / Forzani, Erica (Committee member) / Arizona State University (Publisher)
Created2015